X

We value your privacy!

To make our website work best, we want to use cookies. Some cookies are necessary for the operation of the website, and some improve the user experience. Any data collected are anonymous for which we need your voluntary and revocable consent. For more information on this, see our privacy policy.

Products
FD10.10

FD10.10

FD10.10 universal point position switch,limit control for material storage and transportation,suitable for solid particles, powder, slurry, liquid level measurement.
Type of sample: FD10.10-600.7102.*

For detailed product selection, please contact us Return
Function & Features

Components are not easy to block, break, damage, no regular maintenance

Non-adhesive material,three-terminal shielding technology is adopted

Universal power,24VDC or 220VAC available

Widely used,the process temperature-180℃...+200℃,the pressure goes from vacuum to 100bar

Indicator complete, red light alarm, green light normal, yellow light system failure

Convenient electrical connection, double electrical interface, wiring process is more safe and convenient

Drive ability is strong, 500 Ω between center end and shield end, 150 Ω between shield end and ground

Surge suppression, built-in 1000V spark protection, surge suppression and antistatic 4KV/8KV

Basic parameters
Resolution ratio0.2pF or smaller
Repetitive<1mm (Conductive material);
<20mm (Insulation material)
Alarm wayHigh alarm or low alarm
Alarm light outputRed light:alarm;Green light:normal;
Yellow light:fault alarm
Response time<0.5s
Delay time0…99s (adjustable)
Safety barrierBuilt-in current limiting, quadruple voltage
limiting protection safety grating
Electrostatic spark protectionSurge resistance 1000V
Video protection<10V/m
Electrical parameters
The power supply 24VDC / 220VAC optional
OutputRelay(2set of no+2set of nc)
Contact capacity24VDC / 8A;220VAC / 5A
Load resistance500Ω between the center end and the shield
end, 150Ω between the shielding end and ground
Mechanical parameters
The length of the probe0.5m(standard);0.3…20m(optional)
The probe materialStainless steel / PPS
The connection methodThread NPT¾、the flange
InstallationTop、side
Process connectionBSPT thread(standard),optional NPT or the
flange
Electrical interfaceDouble M20×1.5(NPT1/2'' optional)
Environmental conditions
Process temperature﹣180...+200℃
Environment temperature﹣40...+70℃
Environment humdity<98%RH(at 25℃)
Enclosure protectionIP67
Explosion-proof gradeExd II CT6

Overall dimensions


FD10.10尺寸图.jpg


Wiring diagram


                       24VDC:

                      220VAC:



          ①  1、2the power supply           ②  3、6 nc contacts           ③  4、7common end          ④  5、8 no contacts 



Brochures
Manuals
CAD/CAE
Certificate