FD30G.10

FD30G.10 single cable level meter is mainly used for material measurement of liquid and solid powder.
Type of sample:FD30G.30-1113.1000.10010.*

Cable probe

Accuracy ± 3mm, resolution 1mm

Measurement range 0...30m

It is suitable for measuring conventional liquid medium and solid powder

The process pressure can reach 2.0MPa

The process temperature can reach 250 ℃

Not affected by noise, steam, dust, vacuum, etc

It is not affected by the change of medium density and temperature

FD30G.10B

FD30G.10B guided wave electromagnetic integrated interface meter, which uses guided wave radar combined with segmented electromagnetic detection technology, can realize multi-interface liquid level measurement, and has high cost performance in terms of high reliability and ease of use.
Type of sample:FD30G.10B-2114.1000.10010B15.*

Anti-corrosion rod probe, integrated design

It can simultaneously output the analog quantity signal of oil-water and oil-gas dual interface

The parameters can be set according to the user's requirements, and generally there is no need for calibration and commissioning on site

Measuring range 0... 20m

Accuracy < 0.5%, resolution 1mm

Process pressure can reach 2.0MPa

Process temperature can reach 250 ℃

Not affected by noise, steam, dust, vacuum, etc

Not affected by the change of medium density and temperature

Intelligent self-tuning signal processing technology, low failure rate, maintenance-free

FD30G.20

FD30G.20 single rod level meter is mainly used for material measurement of liquid and solid particles.
Type of sample:FD30G.20-1113.1000.10010.*

Rod probe

Accuracy ± 3mm, resolution 1mm

Measurement range 0...6m

It is suitable for measuring conventional liquid medium

The process pressure can reach 2.0MPa

The process temperature can reach 250 ℃

Not affected by noise, steam, dust, vacuum, etc

It is not affected by the change of medium density and temperature

FD30G.30

FD30G.30 double cable level meter is mainly used for the measurement of solid powder and low dielectric constant liquid.
Type of sample:FD30G.30-1113.1000.10010.*

Double cable probe

Accuracy ± 3mm, resolution 1mm

Measurement range 0...30m

It is suitable for measuring liquid and solid powders with low dielectric constant

The process pressure can reach 2.0MPa

The process temperature can reach 250 ℃

Not affected by noise, steam, dust, vacuum, etc

It is not affected by the change of medium density and temperature

FD30G.40

FD30G.40 level meter, used for level measurement of liquid with low dielectric constant at high temperature and high pressure.
Type of sample:FD30G.40-1113.1000.10010.*

High temperature and high pressure sensor, rod probe or coaxial tube probe

Accuracy ± 3mm, resolution 1mm

Measurement range 0...6m

Suitable for liquid level measurement with low dielectric constant

The process pressure can reach 40.0MPa

The process temperature can reach 400 ℃

Not affected by noise, steam, dust, vacuum, etc

It is not affected by the change of medium density and temperature

FD30G.50

FD30G.50 corrosion resistant level meter, suitable for the measurement of corrosive liquids.
Type of sample:FD30G.50-113.1000.10010.*

Rod type PTFE anti-corrosion probe

Accuracy ± 3mm, resolution 1mm

Measuring range bar 0...6m

Suitable for measurement of corrosive liquids

The process pressure can reach 2.0MPa

The process temperature can reach 180 ℃

Not affected by noise, steam, dust, vacuum, etc

It is not affected by the change of medium density and temperature

FD30G.60

FD30G.60 coaxial tube level meter is suitable for the measurement of low dielectric constant liquid or surface fluctuation liquid.
Type of sample:FD30G.60-1113.1000.10010.*

Coaxial tube probe

Accuracy ± 3mm, resolution 1mm

Measurement range 0...6m

It is suitable for measuring liquid media with low dielectric constant or surface fluctuation

The process pressure can reach 2.0MPa

The process temperature can reach 250 ℃

Not affected by noise, steam, dust, vacuum, etc

It is not affected by the change of medium density and temperature