TA2-D1101.X

TA2-D1101.X

TA2-D1101.X square general-purpose isolated transmitters can be applied to perform linear electronic temperature measurements via RTD or TC sensors, or conversion linear resistors vary in resistance to standard analog current/voltage signals, or power modules and signal isolators for 2-wire transmitters, or process control with standard analog output, or electrical isolation of analog signals, and measurement of floating signals.

For detailed product selection, please contact us Return
Function & Features

2-wire power supply > 15V  

Input: RTD, TC, potentiometer, current, voltage  

Current and voltage output (current output 0...23mA, voltage output 0...10 VDC)  

High measuring accuracy, less than 0.1% set range  

6mm ultra-thin shell design  

Excellent EMC electromagnetic compatibility and noise suppression  

Basic parameters
Input range﹣200…850℃(the user to specify)
AccuracyGreater than 0.1% of the set range
SNRMinimum 60dB(0...100KHz)
Signal dynamic range input24bit
Signal dynamic range output16bit
Response time<1s / 400ms(current /voltage input)
Electrical parameters
Power supply16.8…31.2VDC
Power1.2W
RTD input typePt100 / Pt500 / Pt1000 / Ni50 / 100 / 120 / 1000
Sensor cable resistance<50Ω each line
Sensor current<0.2mA
Influence of sensor cable resistance on
accuracy (3-line)
<0.002Ω/Ω
Sensor fault detectionHave
Sensor short circuit detection<15Ω
Current input measurement range0…23mA
Current input adjustable measuring range0…20mA and 4…20mA
Input resistanceRated 10MΩ
Voltage input measurement range0…12VDC
Measuring range can be set0 / 0.2…1.0 / 1…5.0 / 2…10VDC
2 wire system transmitter power supply>15V / 20mA
Linar resistance input min…max0…10000Ω
RP input min…max10Ω…100KΩ
TC input thermocouple typeB ,E , J , K , N , R , S , T , U , W3 , W5 , LR
Current output0…23mA
Signal range can be set0…0 / 0.2…1 / 0…10 / 0…5 / 1…5 / 2…10 / 1…0 /
1…0.2 / 5…0 / 5…1 / 10…0 / 10…2V
Load(@current output)600Ω
Load stability0.01% F.S / 100Ω
Sensor fault alarm output0 / 3.5 / 23mA /without
Upper/lower current in accordance with
NAMUR NE43 standard
23mA/3.5mA
Current limit28mA
Voltage output signal range0…10VDC
Load(@voltage output)10KΩ
Mechanical parameters
Structure size113×6.1×115mm(H×W×L)
Weight(about)70g
DIN typeDIN EN 60715/35mm
Wire specifications0.13×2.5mm²/AWG(26…12 the winding)
Screw terminal moment0.5Nm
Vibration-proof specificationIEC 60068-2-6
2…25Hz±1.6mm
25…100Hz±4g
Environmental conditions
Operating temperature﹣25…+70℃
Storage temperature﹣40…+85℃
Calibration temperature20…28℃
Relative humidity<95%RH(No condensation)
Protection class (housing/terminal)IP20
Installation conditionContamination level 2 & measurement /
overpressure level Ⅱ