Products
FD-LRW

FD-LRW

FD-LRW collision warning laser radar (internal rotation) using TOF scheme, can achieve 270 degrees of two-dimensional scanning,Determine whether there are obstacles in the set area.
Type of example:FD-LRW30A-PEZ.*

For detailed product selection, please contact us Return
Function & Features

The scanning frequency is 3-11Hz and the angular resolution is 1 degree  

Connect the radar to set the monitoring area through the USB interface of PC, and each area can set three independent areas freely  

Detection area can be switched by input (up to 15)  

The front of the anti-collision warning lidar is 0 degrees  

Collision avoidance detection between devices during movement  

AGV (automatic navigation vehicle) obstacle detection  

Robot obstacle avoidance  

Security security - building intrusion protection  

Auto driving  

Space mapping, uav and other fields  

Basic parameters
Range5m / 10m / 20m / 30m / 50m optional
Dead zone 0.15m
Light sourceLaser,class 1
Scanning angle270°(Can be set freely, the origin is the
scanning center position)
Scanning frequency10Hz
Angular resolutionE type:1°;H type:0.36°
Distance accuracy±2mm
Range resolution 1mm
Monitoring area typeAssociated and independent are optional
Locale output 1Free setting within the range
Locale output 2,3Rectangle setting/sector setting/percentage
setting
Monitoring area settingMonitoring area conversion: through import
1,2,3,4 to set the area
Import 1, 2, 3 , 4 are at low power times at
the same time, no collision avoidance area is set
Output response time<150ms(scanning speed 1rec/100ms)
Input response timePeriod: 1 scanning time(100ms)
Indicator lightBlinking yellow (left) indicates that the
system is running normally.
Red light (On the right, near the USB)
Blinking Indicates that there is an obstacle
in the area
Electrical parameters
Power supply24V DC(10…30VDC)
Supply current<300mA
OutputPNP open collector output, divided into
normally open and normally closed (can be
modified by upper computer software)
Input(1-4)Photoelectric coupling input, which can be
used to switch monitoring areas
Mechanical parameters
Impact500m/sec2,11ms
Vibration5…2000Hz,3Grms
SizeΦ80×77.3mm(D×H)
Weight397g
Environmental conditions
Operating temperature﹣20…+70℃
Protection classIP67

Overall dimensions


FD-LRW尺寸图~英.jpg